CAMERA & DETECTORS
Light Radiometer
Lab Radiometer – ILT5000
The ILT5000 is “The ILT1700 for the 21st Century” improving on the industry standard with rapid measurements (up to 100 Hz), a broader dynamic range (100fA to 1mA), extensive supporting software apps, wireless coomunication, internal data storage, and 4-20 mA output.
The broad linear dynamic range of the ILT5000 and the SMA input connector allow the meter to also serve as a broad range, highly sensitive and accurate range pico ammeter. The ILT5000 supports numerous light measurement applications including, but not limited to; Radiometry, Photometry, Reasearch, UVGI- Sterilization, Solar, Photoresist, Optical Radiation Hazard, Phototherapy, Photo-degradation, Plant Growth and more.
Features
- 10 Decade Dynamic Range of Optical Analysis
- Wireless Transmitter, Built-in
- Made in USA
- Autorange, Autodark, Auto-sample with User Control Options
- 4-20 mA Output
- “Set It & Forget It” Remote Data Logging
- Built-in Re-Chargeable Battery Pack
- Multi-System Simultaneous Continuous Monitoring
- DataLight II Complementary Light Measurement and Data Collection Software Apps
- Labview Compatible
- NIST-Traceable/ISO17025 Accredited Calibration and Certificate
- Backwards Compatible with ILT1700 SED Detector/Filter/Optics
- Sample Rate Up to 100 Hz, Programmable
- Custom & OEM Inquiries Welcome
Key Applications
- Radiometry
- Photometry
- Reasearch, UVGI-Sterilization
- Solar, Photoresist
- Optical Radiation Hazard
- Phototherapy
- Photo-degradation
- Plant Growth and more
Key Specifications
Meter | Measurement Range | 100 fA – 1 mA |
Reverse Bias | 2 Voltages/selectable | |
Automatic Ranging | Rapid switching through all current levels | |
WiFi | Enabled | |
Operating Temperature | -40 to 85°C (Calibrated Irradiance 0-40°C) | |
USB | USB2, Including Power, for Single and Multiple Systems | |
USB Current Draw | 500 mA max, 250 mA typical | |
Size | 1-3/5” H x 5” W x 7” L | |
Input connector | D-Sub and/or SMA | |
CE certified | No rf/noise | |
Software | CLI | Command line interface sent over a serial port |
Trigger | TTL, for synchronization of measurement | |
Data Storage | Internal (includes units, date and time stamps) | |
Time Line | Scheduled data acquisition | |
Integration Range | Unlimited dosage/exposure | |
Transmission/Reflectance | 100% | |
Optical Density | 0.00 to 4.00 | |
Zero | Dark or ambient subtraction | |
Direct Reading | Current or calibrated optical units | |
Apps | Meters, CLI, Bar, Trend and Reports apps all included | |
Minimum Computer System Requirements | Tablet | Minimum 8” tablet |
Operating System | Windows 7 or 8 | |
Memory/RAM | Minium 1 GB RAM (on board) | |
Storage | 32GB (flash or SSD) | |
Processor | at least1.83GHz (with minimum 2MB Cache) | |
Ports | 1 Micro-USB 2.0 Port | |
Wi-Fi® Wireless networking | 802.11b/g/n |