TCSPC Life Time (PICOQUANT)

Fluorescence Life time Spectrometers

FluoMic add-on

The FluoMic add-on provides a fast, easy, and reliable way to bring the power of the FluoTime 300 steady-state and time-resolved luminescence spectrometer with a micrometer sized, positionable observation volume. On the spectrometer’s side, installation of the FluoMic requires only sliding the mounting unit into the sample chamber.

Thank to its pre-aligned optical fibers, both pulsed and CW light sources of the FluoTime 300 can be used to excite a sample located in an external device. The FluoMic includes a special microscope fi ber coupler unit that can be attached to various microscopes (such as, e.g., the Olympus BX43).
Emitted light is collected from a small area (down to 2 μm) and brought back to the detection arm of the FluoTime 300 via a detection fiber. Thus the outstanding fl exibility in both spectral (from UV to NIR) and time (from ps to ms) range of the FluoTime 300 can be extended to samples located outside the spectrometer and then measured with spatial resolution.

Features
  • Interface your FluoTime 300 to a microscope via pre-aligned optical fi bers
  • Enable time-resolved and steady-state measurements
  • Gather data from any point of the sample
  • Excite samples with the FluoTime 300’s pulsed or CW source
  • Easy to use: no time consuming alignment needed
  • Bring the power and versatility of the FluoTime 300 to your sample
Key Applications
  • Semiconductor wafer testing and analysis
  • Investigation of solar cell materials and Perovskites
  • Studying minerals and crystals
  • Analysis of polymers and composites
  • Characterizing LED materials
Key Specifications
Microscope unitType microscope body (standard)BX43 (others on request)
Objectives (standard, as needed)Air objectives with 20x and 40x magnification
Objectives (optional, as needed)Various high-end objectives available
(Oil/Water immersion, air spaced, IR-enhanced, or long working distance
objectives)
Spot size excitation with CW lamp170 µm (20x magnification)
Spot size excitation with laser60 µm (20x magnification)
Spot size emission2 µm (100x magnification)
10 µm (20x magnification)
Wavelength range excitation370 - 900 nm
Wavelength range emission370 - 1700 nm (depends on detectors used)
Excitation sources (recommended)Light sourceLaser Diode Heads
(LDH Series)
Picosecond Laser Mo-
dule (VisUV / VisIR)
CW Xenon lamp
Wavelengths (nm)375 - 900 nm532, 560, 590, 766 nm370 - 900 nm
Pulse width60 - 200 psca. 80 ps---
Repetition rateup to 80 MHzup to 80 MHz---
Operating environmentPower requirements110 - 230 V, 50/60 Hz
Dimensions (base unit)Micrsocope unit
(depends on microscope used)
400 × 300 × 600 mm (w × d × h)